Here are some of our most popular models. Click on the links to get more info.
We also offer Custom-Fit sizes for special applications.
Contact Us for any custom fit applications you need.
Resource Center Module - for charging the 36 Volt Battery Array Fits Most
EZ-GO-Yamaha-Club Cart Flat Roof Extended"Power
measured in Watts can be determined by multiplying the operational
Voltage, typically either 36V or 48V based on your cart battery array,
with the Current supplied by the panel in Amps. The Open Circuit Voltage
is regulated down by the charge controller to supply the appropriate
voltage to your battery array."
36V-LG TOP
Watts=Voltage X Amps |
|
Operating Current |
4.9 amps |
Operating Voltage |
15.5 Volts |
Constant |
42.3 Volts |
Break Through Technology /Smart Controller Changes 15.5 Volts to 36 or 48 |
36V System Maintained by 42.3 V |
Nominal Operating Cell Temp |
140°F |
Cell Technology |
Thin Film Amorphous Silicon |
Overall Dimensions |
37.2" X 72.44" |
Solar Panel Weight |
5.0 lbs.+- |
Back To The Top
* Amorphous cells with different light absorption properties
deposited continuously, one on top of another, to capture the broad
solar spectrum more effectively. This increases the energy conversion
efficiency of the multi-cell device and improves performance stability.
BACKING: Ethylene Propylene Copolymer Tape is a high performance,
non-drying, non hardening, industrial grade tape formulated with
reinforced rubber and inert inorganic, non asbestos fillers. Earth
Care's custom built Peel and Stick affords excellent webbing and
elongation properties. It also has the superior weathering characteristics
and retains adhesion and elasticity in weather extremes for prolonged
periods. In fact 40 degrees below to 170 degrees high.
CONTROLLERS: Operating Voltage and Operating Current at AM 1.5.
Power performance may vary +/- 10% due to temperature variation,
spectral variation, and related effects.
Amps, Volts, Watts, Ohms ohm
... watt amp volts?
Watts = Volts x
Amps Watts is a unit of power having the dimensions (energy
per unit time): M L2 / T2 divided by T = M
L 2 / T 3 Note: A kilowatt-hour is a
1000 watts times one hour = an energy unit. Volt is a unit
of force (F=ma): ML / T2
So that Amps have the dimensions: L / T
Resource Center module PVX Top
for charging the 36/48Volt Battery Array“Power
measured in Watts can be determined by multiplying the operational
Voltage, typically either 36V or 48V based on your cart battery
array, with the Current supplied by the panel in Amps. The Open
Circuit Voltage is regulated down by the charge controller to
supply the appropriate voltage to your battery array.” |
36V-PVX TOP
Watts=Voltage X Amps |
|
Operating Current |
5 85 amps |
Operating Voltage |
15 V |
Break Through Technology /Smart Controller Changes 15.5 Volts to 36 or 48 |
48 Volt System Maintained by 56.4 Volts |
Constant |
42.3 Volts |
Nominal Operating Cell Temp |
140°F |
Cell Technology |
Thin Film Amorphous Silicon |
Overall Dimensions |
38.2" x 86.1" |
Solar Panel Weight |
4.75 lbs. |
Back To The Top
* Amorphous cells with different light absorption properties deposited continuously,
one on top of another, to capture the broad solar spectrum more effectively.
This increases the energy conversion efficiency of the multi-cell device and
improves performance stability.
BACKING: Ethylene Propylene Copolymer Tape is a high performance, non-drying,
non hardening, industrial grade tape formulated with reinforced rubber and
inert inorganic, non asbestos fillers. Resource Center’s custom built Peel and Stick
affords excellent webbing and elongation properties. It also has the superior
weathering characteristics and retains adhesion and elasticity in weather extremes
for prolonged periods. In fact 40 degrees below to 170 degrees high.
CONTROLLERS: Operating Voltage and Operating Current at AM 1.5. Power performance
may vary +/- 10% due to temperature variation, spectral variation, and related
effects.
Amps, Volts, Watts, Ohms ohm
… watt amp volts?
Watts = Volts x Amps Watts
is a unit of power having the dimensions (energy per unit time): M L2 / T2
divided by T = M L 2 / T 3 Note:
A kilowatt-hour is a 1000 watts times one hour = an energy unit. Volt
is a unit of force (F=ma): ML / T2
So that Amps have the dimensions: L / T
Resource Center module PVX Top - for charging the 36/48Volt Battery Array“Power
measured in Watts can be determined by multiplying the operational Voltage,
typically either 36V or 48V based on your cart battery array, with the Current
supplied by the panel in Amps. The Open Circuit Voltage is regulated down by
the charge controller to supply the appropriate voltage to your battery array.”
48V-PVX TOP
Watts=Voltage X Amps |
|
Operating Current |
5 85 amps |
Operating Voltage |
15 V |
Break Through Technology /Smart Controller Changes 15.5 Volts to 36 or 48 |
48 Volt System Maintained by 56.4 Volts |
Constant |
56.4 Volts |
Nominal Operating Cell Temp |
140°F |
Cell Technology |
Thin Film Amorphous Silicon |
Overall Dimensions |
38.2? x 86.1? |
Solar Panel Weight |
4.75 lbs. |
Back To The Top
* Amorphous cells with different light absorption properties deposited continuously,
one on top of another, to capture the broad solar spectrum more effectively.
This increases the energy conversion efficiency of the multi-cell device and
improves performance stability.
BACKING: Ethylene Propylene Copolymer Tape is a high performance, non-drying,
non hardening, industrial grade tape formulated with reinforced rubber and
inert inorganic, non asbestos fillers. Resource Center’s custom built Peel and Stick
affords excellent webbing and elongation properties. It also has the superior
weathering characteristics and retains adhesion and elasticity in weather extremes
for prolonged periods. In fact 40 degrees below to 170 degrees high.
CONTROLLERS: Operating Voltage and Operating Current at AM 1.5. Power performance
may vary +/- 10% due to temperature variation, spectral variation, and related
effects.
Amps, Volts, Watts, Ohms ohm
… watt amp volts?
Watts = Volts x Amps Watts
is a unit of power having the dimensions (energy per unit time): M L2 / T2
divided by T = M L 2 / T 3 Note:
A kilowatt-hour is a 1000 watts times one hour = an energy unit. Volt
is a unit of force (F=ma): ML / T2
So that Amps have the dimensions: L / T
Resource Center module Villager 8 Top - for charging the 36/48Volt Battery Array
"Power measured in Watts can be determined by multiplying the operational Voltage, typically either
36V or 48V based on your cart battery array, with the Current supplied by the panel in Amps.
The Open Circuit Voltage is regulated down by the charge controller to supply the appropriate voltage to your battery array."
FS-CCV2- Villager 8
Watts=Voltage X Amps |
|
Operating Current |
8.0 amps |
Operating Voltage |
15 Volts |
Constant |
42.3 Volts |
Break Through Technology /Smart Controller Changes 15.5 Volts to 36 or 48 |
48V System Maintained by 56.4 V |
Nominal Operating Cell Temp |
140°F |
Cell Technology |
Thin Film Amorphous Silicon |
Overall Dimensions |
37.20" X 112.0" or 37.20" X 120.0" |
Solar Panel Weight |
6.75 lbs.+- |
Back To The Top
* Amorphous cells with different light absorption properties
deposited continuously, one on top of another, to capture the broad
solar spectrum more effectively. This increases the energy conversion
efficiency of the multi-cell device and improves performance stability.
BACKING: Ethylene Propylene Copolymer Tape is a high performance,
non-drying, non hardening, industrial grade tape formulated with
reinforced rubber and inert inorganic, non asbestos fillers. Resource Center's
custom built Peel and Stick affords excellent webbing and
elongation properties. It also has the superior weathering characteristics
and retains adhesion and elasticity in weather extremes for prolonged
periods. In fact 40 degrees below to 170 degrees high.
CONTROLLERS: Operating Voltage and Operating Current at AM 1.5.
Power performance may vary +/- 10% due to temperature variation,
spectral variation, and related effects.
Amps, Volts, Watts, Ohms ohm
... watt amp volts?
Watts = Volts x
Amps Watts is a unit of power having the dimensions (energy
per unit time): M L2 / T2 divided by T = M
L 2 / T 3 Note: A kilowatt-hour is a
1000 watts times one hour = an energy unit. Volt is a unit
of force (F=ma): ML / T2
So that Amps have the dimensions: L / T
Resource Center module DW Top - for charging the 36/48Volt Battery Array
"Power measured in Watts can be determined
by multiplying the operational Voltage, typically either 36V or 48V
based on your cart battery array, with the Current supplied by the
panel in Amps. The Open Circuit Voltage is regulated down by the
charge controller to supply the appropriate voltage to your battery
array."
FS-DW Large Top
Watts=Voltage X Amps |
|
Operating Current |
4.2 amps |
Operating Voltage |
15V |
Break Through Technology /Smart Controller Changes 15.5 Volts to 36 or 48 |
48 Volt System Maintained by 56.4 Volts |
Constant |
56.4 |
Nominal Operating Cell Temp |
140°F |
Cell Technology |
Thin Film Amorphous Silicon |
Overall Dimensions |
51.3 X 45.20" |
Solar Panel Weight |
4.75 lbs. |
Back To The Top
* Amorphous cells with different light absorption properties deposited continuously,
one on top of another, to capture the broad solar spectrum more effectively.
This increases the energy conversion efficiency of the multi-cell device and
improves performance stability.
BACKING: Ethylene Propylene Copolymer Tape is a high performance, non-drying,
non hardening, industrial grade tape formulated with reinforced rubber and
inert inorganic, non asbestos fillers. Resource Center's custom built Peel and Stick
affords excellent webbing and elongation properties. It also has the superior
weathering characteristics and retains adhesion and elasticity in weather extremes
for prolonged periods. In fact 40 degrees below to 170 degrees high.
CONTROLLERS: Operating Voltage and Operating Current at AM 1.5. Power performance
may vary +/- 10% due to temperature variation, spectral variation, and related
effects.
Amps, Volts, Watts, Ohms ohm
... watt amp volts?
Watts = Volts x Amps Watts
is a unit of power having the dimensions (energy per unit time): M L2 / T2
divided by T = M L 2 / T 3 Note:
A kilowatt-hour is a 1000 watts times one hour = an energy unit. Volt
is a unit of force (F=ma): ML / T2
So
that Amps have the dimensions: L / T
|
|